ZOZEN Boiler Co., Ltd. professional engineers will analyze the customer's needs in depth and provide the most suitable complete set of design solutions and boiler system configuration. ZOZEN has 6 series more than 400 varieties products include gas / oil fired boilers, biomass-fired boilers, coal-fired boilers and thermal oil heaters. Our products are widely used in chemical, paper, food processing, feed industry, central heating, thermal power plants, and etc.

Products You May Need

WNS gas/oil fired boiler

1-20 t/h | 0.7-2 Mpa

DZL biomass fired steam boiler

2 – 20 t/h | 1 - 2.5 Mpa

SZL coal fired steam boiler

4 - 35 t/h | 1.0 - 2.5 Mpa

Our Customer Cases

6tph SZL series packaged chain grate steam boiler project in Bangladesh

Location: Bangladesh

Equipment: SZL6-1.25-AII

4 tph DZL series chain grate steam boiler for the feed industry in Indonesia

Location: Central Java, Indonesia

Equipment: DZL4-1.25-AII

recommended abma & asme boiler water limits boiler ?

Recommended ABMA & ASME Boiler Water Limits Boiler ?

RECOMMENDED ABMA & ASME BOILER WATER LIMITS* DRUM OPERATING PRESSURE (psig) 0-300 301-450 451-600 601-750 751-900 901-1000 1001-1500 1501-2000 STEAM TDS max (ppm) 0.2-1.0 0.2-1.0 0.2-1.0 0.1-0.5 0.1-0.5 0.1-0.5 0.1 0.1 BOILER WATER TDS max (ppm) ALK max (ppm) TSS Max (ppm) Conductivity max (µmho/cm) Silica max (ppm Si0 2) 700-3500 350 15 1100-5400 150 600 …

Get a Quote
rules and regulations for boiler and pressure ?

RULES AND REGULATIONS FOR BOILER AND PRESSURE ?

(d) Electric Boiler - A power boiler or heating boiler in which the source of heat is electricity. (e) Miniature Boiler - A power boiler or high-temperature water boiler which does not exceed the following limits: 1. 16" inside diameter of shell; 2. 20 sq. ft. heating surface (not applicable to electric boilers);

Get a Quote
steam boilers high limit - ntswitgoedservice.

Steam Boilers High Limit - ntswitgoedservice.

P47 Series Steam Pressure Limit Controls Installatio. 2018-9-26 · Steam Pressure Limit Controls Application The P47 controls are designed for high limit, cutout, or operating control applications. When used as a limit or cutout control, the P47 is intended primarily to limit the pressures in steam …

Get a Quote
cga, cgi, cgs, eg, egh, lgb, peg, p

CGa, CGi, CGs, EG, EGH, LGB, PEG, P

CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers 4 Part Number 550-110-592/0709 Boiler components 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 6 Inducer (CGi and CGs only) 7 Vent damper (CGa only) 8 Water temperature limit switch 9 Transformer 10 Spill switch (CGa only) 11 Air pressure switch (CGi and CGs only) 12 Rollout thermal fuse element

Get a Quote
steam systems - cleaver-brooks | complete boiler room .

STEAM SYSTEMS - Cleaver-Brooks | Complete Boiler Room .

flexibility exists and yet operating characteristics of equipment in the steam-use facility either set or limit the range of operating pressure of the boiler. 2. Determine the steam load characteristics and ultimately the profile of the steam-use facility in its entirety (see Section I1). It is important to understand

Get a Quote
the national board of boiler and pressure vessel inspecto

The National Board of Boiler and Pressure Vessel Inspecto

The secondary device referenced above for both steam and hot-water boilers is referred to as a high-limit control and under normal conditions, would never be called upon to operate. However, if the primary, or operating, control should fail, the high-limit control must operate, stopping the burner or other source of heat.

Get a Quote
cleaver-brooks - complete boiler room solutio

Cleaver-Brooks - Complete Boiler Room Solutio

High-Limit Control. Controls over pressure. Set above the operating limit off point, this control has a fixed differential so the switch is closed unless the set point is reached and it …

Get a Quote
water and steam boilers - grainger industrial supp

Water and Steam Boilers - Grainger Industrial Supp

Oil-fired boilers feature high-limit controls, aquastat relay, temperature/pressure indicator and ASME pressure relief valve. Check out the entire cast-iron steam boiler selection at Grainger today!

Get a Quote
pressuretrol steam pressure controllers from honeywe

Pressuretrol Steam Pressure Controllers from Honeywe

Honeywell pressuretrol controller for safety control to shut down the burner if the steam pressure rises above a safe level on steam boilers with a range of 3-15 psi. This pressuretrol breaks at set point on pressure rise and makes on set point on pressure fall. Honeywell PA404A1033 - Pressuretrol Controller.5-9 psi SKU: HN1442

Get a Quote
best boiler buying guide - consumer repor

Best Boiler Buying Guide - Consumer Repor

Jun 23, 2020· Most boilers produce steam or hot water using natural gas or heating oil, and all are either condensing or non-condensing (see below). ... • Test the pressure-relief valve and high-limit …

Get a Quote
aquastat temperature control | boiler componen

Aquastat Temperature Control | Boiler Componen

Based on the aquastat setting, this will limit the high temperature in the boiler to prevent overheating. The cutoff temperature for most hot water boilers is 180° F. There is a differential setting to make sure the boiler does not short cycle or run unnecessarily.

Get a Quote
high capacity horizontal steam boil

High Capacity Horizontal Steam Boil

High Capacity Horizontal Steam Boiler Steam Pressures to 135 psig Steam Capacity (452 - 4,882 Lbs/Hr @ 0 - 135 psig) 150 - 1,620 kW (512 - 5,527 Mbh)

Get a Quote
hp603 - boiler control settings - burnham commerci

HP603 - Boiler Control Settings - Burnham Commerci

Jun 23, 2009· Set the L4006E high limit to 230°F with a differential of 5°F. The high limit is a safety device only and will stop the burner in case the operating control malfunctions. On a call for heat, the burner will start and run until the water temperature reaches the L4006A’s operating setpoint of 180°F and the burner will shut off.

Get a Quote
boiler water limit:- - altr

Boiler water Limit:- - Altr

This value will limit the silica content of the steam to 0.25 ppm as a function of selective. Feed Water & Boiler water Characteristics as per IS:10392-1982 1.FEED WATER Parameters Upto 20 Kg/cm2 21 Kg/cm2 to 39 Kg/cm2 40 Kg/cm2 to 59 Kg/cm2 Unit Total Hardness <10 <1.0 <0.5 ppm as CaCO 3 pH Value 8.5-9.5 8.5-9.5 8.5-9.5 Dissolved Oxygen

Get a Quote
controlling tds in the boiler water | spirax sar

Controlling TDS in the Boiler Water | Spirax Sar

Conventional shell boilers are normally operated with the TDS in the range of 2 000 ppm for very small boilers, and up to 3 500 ppm for larger boilers, provided the: Boiler is operating near to its design pressure. Steam load conditions are not too severe. Other boiler water conditions are correctly controlled.

Get a Quote
hvac - steam boiler faulty high limit switch - youtu

HVAC - Steam Boiler Faulty High Limit Switch - YouTu

Oct 09, 2018· HVAC Technicians that start up heating equipment such as boilers and furnaces need to be mindful of safety switches such as limits and interlocks. Each one should be …

Get a Quote
heating system boiler limit controls & strap-on aquasta

Heating System Boiler Limit Controls & Strap-On Aquasta

On heating boilers where individual limit controls are installed, you will find two similar devices, but mounted at different locations on the boiler, controlling the boiler's HIGH limit, or cut-off on a call for heat, and the boiler's LOW limit or cut-on point as the boiler water temperature falls.

Get a Quote
boiler basics part 3 - steam - hvac scho

Boiler Basics Part 3 - Steam - HVAC Scho

Jan 14, 2017· These controls aren’t typically seen on smaller single or 2 stage burners, but in larger burners that require different burner firing rates depending on steam load and requirements. They contain the same terminals as the operating control listed above ( R,W, and B), but act completely different.

Get a Quote
boilers - commercial & residential | weil-mcla

Boilers - Commercial & Residential | Weil-McLa

Weil-McLain offers a broad spectrum of high efficiency gas-fired, oil-fired and combination oil/gas boilers for commercial use. Whatever your needs --heating a restaurant, hotel, casino, or any other commercial or industrial facility--depend on Weil-McLain boilers to provide the solution that delivers cost savings, energy efficiency and system flexibility.

Get a Quote
basic water treatment of steam boile

BASIC WATER TREATMENT OF STEAM BOILE

May 02, 2000· The impurities found in the makeup water will build up in the boiler as the water turns to steam leaving most impurities behind. There are known maximum limits for these impurities, which can and will be surpassed without proper blow down. The maximum concentration allowable by the limits can be expressed as the maximum cycles for that water ...

Get a Quote
13 ncac 13 .0406 high pressure or temperature limit ?

13 NCAC 13 .0406 HIGH PRESSURE OR TEMPERATURE LIMIT ?

13 NCAC 13 .0406 HIGH PRESSURE OR TEMPERATURE LIMIT CONTROL (a) Each automatically fired steam boiler or system of commonly connected steam boilers shall have at least one steam pressure control that will shut off the fuel supply to each boiler or system of commonly connected boilers when the pressure reaches a preset maximum operating pressure.